- OSHA/PART 1910 1910.146
- Confined Space
(PRCS) Permit-required Confined Space
Permit-required confined space (permit space)" means a confined space that has one or more of the following characteristics:
- Contains or has a potential to contain a hazardous atmosphere.
- Contains a material that has the potential for engulfing an entrant.
- Has an internal configuration such that an entrant could be trapped or asphyxiated by inwardly converging walls or by a floor which slopes downward and tapers to a smaller cross-section.
- Contains any other recognized serious safety or health hazard.